A blend is tested by separating its components by HPLC, identifying each by mass spectrometry and reporting each component’s amount on the certificate.

Updated November 20, 2026 · Simple Life Science

For laboratory research use only. Not for human or animal use. This page covers chemistry, identity and paperwork only. It gives no use, preparation or administration instructions.

A blend vial holds two or more separate compounds. Testing it means proving each one is there, is the right molecule and is present in the right amount. Here is how that is done and what to look for on a blend certificate.

How the lab tests a blend

  • Separate. HPLC splits the mix into peaks, one per component, plus any impurities.
  • Identify. Mass spectrometry measures each peak and matches it to one component’s expected mass.
  • Measure. Each component’s amount is worked out against a reference, so the certificate can list them one by one.
  • Report. The certificate lists each component, its measured amount and the purity.

Blends we supply

Blend Components (avg. MW, g/mol) Catalog item
BPC-157/TB-500 Blend BPC-157 (1419.5); TB-500 (Thymosin Beta-4) (4963) BPC-157/TB-500 Blend
Ipamorelin/CJC-1295 (No DAC) Blend Ipamorelin (711.9); CJC-1295 (no DAC) (3367.9) Ipamorelin/CJC-1295 (w/o DAC)
GLOW Blend (GHK-Cu/BPC-157/TB-500) GHK-Cu (402.92); BPC-157 (1419.5); TB-500 (Thymosin Beta-4) (4963) GHK-CU/BPC-157/TB-500 GLOW Blend
KLOW Blend (GHK-Cu/BPC-157/TB-500/KPV) GHK-Cu (402.92); BPC-157 (1419.5); TB-500 (Thymosin Beta-4) (4963); KPV (342.43) GHK-CU/BPC-157/TB-500/KPV KLOW Blend
Tesamorelin/Ipamorelin Blend Tesamorelin (5136); Ipamorelin (711.9) Tesamorelin/Ipamorelin 12/2MG
MOTS-c/GHK-Cu/KPV Blend MOTS-c (2174.6); GHK-Cu (402.92); KPV (342.43) MOTS-C/GHK-CU/KPV Blend
GHK-Cu/KPV Blend GHK-Cu (402.92); KPV (342.43) GHK-Cu/KPV Blend
SLUBAM (SLU-PP-332 + BAM15) Capsules SLU-PP-332 (290.3); BAM15 (340.29) SLUBAM (BAM15 50MG & SLUPP332 250MCG) 60 Capsules
BPC-157/KPV/Larazotide Capsule Formula BPC-157 (1419.5); KPV (342.43); Larazotide (725.8) Gut Inflammation Research (BPC/KPV/Larazotide)

What makes blends harder to test

  • Components with very different sizes (for example GHK-Cu at about 403 g/mol next to thymosin beta-4 at about 4963 g/mol) need a gradient that resolves both.
  • Small polar molecules come off the column early, sometimes near the solvent front.
  • Copper complexes can lose copper during MS, so free GHK may show alongside GHK-Cu.
  • A component at a small share of the mix gives a small peak, so its amount has a wider margin.

Checklist for a blend certificate

  • Each component is named, with an identity result.
  • Each component has a measured amount.
  • The lot number matches the vial.
  • The certificate can be checked on the testing lab’s site.

Related pages

Common questions

Does a blend COA test every component?

Yes. Each component is identified by mass spectrometry and its amount is reported separately.

Why does a blend show more than one main peak?

Each component is a separate molecule and gives its own peak.

Are blend components chemically bonded?

No. They are separate molecules mixed in one vial or capsule.