The certificate for AOD-9604 should show a mass spectrometry identity match to 1815.1 g/mol (1813.8604 Da monoisotopic) and an HPLC purity figure for the exact lot. Latest published lot: AOD10-062026-4, 99.78% purity, reported 2026-06-07.
For laboratory research use only. Not for human or animal use. This page covers chemistry, identity and paperwork only. It gives no use, preparation or administration instructions.
Latest published lots
| Product as named on the COA | Lot | HPLC purity | Identity (MS) | Report date | |
|---|---|---|---|---|---|
| AOD-9604 10mg | AOD10-062026-4 |
99.78% | Confirmed | 2026-06-07 | COA |
| AOD-9604 5mg | AOD05-032026-1 |
99.23% | Confirmed | 2026-03-12 | COA |
| AOD-9604 5mg | AOD0128202G-J |
99.714% | Confirmed | 2026-02-05 | COA |
Lots as listed in the Simple Life Science COA library on November 20, 2026. Older lots and newer releases can be found with the COA lot lookup or in the documentation library. Testing lab: Freedom Diagnostics Testing; each certificate can also be checked on the lab’s own site with its search code.
What the identity result should match
Identity is confirmed by mass spectrometry: the measured mass must match AOD-9604. Expected values from the PubChem formula (C78H123N23O23S2): average molecular weight 1815.1 g/mol, monoisotopic mass 1813.8604 Da. In positive-mode electrospray, these are the ions to expect:
| Ion | Expected m/z (monoisotopic) |
|---|---|
| [M+H]+ | 1814.8676 |
| [M+2H]2+ | 907.9375 |
| [M+3H]3+ | 605.6274 |
| [M+4H]4+ | 454.4724 |
| [M+5H]5+ | 363.7793 |
| [M+6H]6+ | 303.3173 |
m/z values are calculated from the monoisotopic mass plus protons (1.00728 Da each). Real spectra also show isotope peaks just above each value.
Things to check on a AOD-9604 certificate
- The disulfide bridge joins Cys7 and Cys14. The open (reduced) chain is 2 Da heavier than the closed ring, so a +2 Da peak points to a broken bridge.
- 2 sulfur atoms add a small extra peak 2 Da heavier (sulfur-34).
How purity is measured
Purity is measured by reversed-phase HPLC with UV detection. Peptide bonds absorb strongly near 214-220 nm, so every peptide species in the sample shows up. AOD-9604 has 0 tryptophan and 1 tyrosine residue; these also absorb near 280 nm. The purity figure is the main peak’s share of the total peak area. It says nothing about water or counter-ions; that is what net peptide content covers.
Fields on a Simple Life Science COA
| Field | What it tells you |
|---|---|
| Accession number and search code | The lab’s own record numbers. Use the search code to look the report up on the testing lab’s site. |
| Lot | Must match the lot printed on your vial label. |
| Net peptide content (or amount) | How much of the compound the lab measured in the sample. For peptides this excludes water and counter-ions. |
| Purity | HPLC main-peak area percentage. |
| Identity | Mass spectrometry result: confirmed means the measured mass matched the expected compound. |
| Appearance | For example white lyophilized powder; GHK-Cu is blue. |
| Endotoxin (when listed) | Replicate pass/fail results, when that test was ordered for the lot. |
Every batch stays in quarantine until its test comes back passing; only then is it released for sale. See batch quarantine and release.
Related pages
- AOD-9604 molecular weight, formula and structure
- How to read a peptide COA
- Net peptide content and salt forms
- AOD-9604 5MG
- AOD-9604 10MG
- Compound chemistry index (all structure and COA pages)
- Compound reference table: CAS, formula and MW for every compound
- Purity grades, HPLC and mass spec explained
- How batch quarantine and release works
- COA lot lookup: find any lot’s certificate
Common questions
Does AOD-9604 from Simple Life Science come with a COA?
Yes. Each released lot has a certificate from Freedom Diagnostics Testing. The most recent published lot is AOD10-062026-4 (reported 2026-06-07).
What mass should the AOD-9604 COA show?
The identity result should match AOD-9604: about 1815.1 g/mol average, 1813.8604 Da monoisotopic.
How do I check that a COA belongs to my vial?
Match the lot number on the vial to the lot on the certificate, then look the lot up in the COA lot lookup on our site or with the search code on the lab’s site.
What happens to a batch that fails testing?
It stays in quarantine and is not released for sale.
Research use only. Not for human or animal use. Simple Life Science is operated by Melex Technologies Inc., 6586 W Atlantic Ave Ste #1112, Delray Beach, FL 33446.